Bendix EC80 Brake ECU

View CSAF

Summary

Successful exploitation of these vulnerabilities could allow an attacker to cause the loss of ABS functions, steering assist, speedometer, shifting capabilities, or disable automatic traction control.

The following versions of Bendix EC80 Brake ECU are affected:

  • EC80ESP+ J1708 Z228999
  • EC80ESP+ 6S/6M Z228999
  • EC80ESP+ PLC Z228999 
  • EC80ESP+ 2nd CAN Z228999
  • EC80ESP+ Integrated TPMS Z228999
  • EC80ESP 6S/6M Z266494 
  • EC80ESP PLC Z266494 
  • EC80ESP 2nd CAN Z266494
  • EC80ESP CAN Gateway Z266494 
  • EC80ESP 4S/4M Z286098 
  • EC80ESP PLC Z286098 
CVSS Vendor Equipment Vulnerabilities
v3 7.5 Bendix Bendix EC80 Brake ECU Stack-based Buffer Overflow, Out-of-bounds Write, Use of Hard-coded Credentials

Background

  • Critical Infrastructure Sectors: Transportation Systems
  • Countries/Areas Deployed: United States, Canada
  • Company Headquarters Location: United States

Vulnerabilities

Expand All +

CVE-2026-67560

The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to crash the ECU. A crafted payload can then be used to remotely execute arbitrary code or inject arbitrary CAN bus traffic. This could cause the loss of the ABS function, steering assist, speedometer, and shifting.

View CVE Details


Affected Products

Bendix EC80 Brake ECU
Vendor:
Bendix
Product Version:
Bendix EC80ESP+ J1708: Z228999, Bendix EC80ESP+ 6S/6M: Z228999, Bendix EC80ESP+ PLC: Z228999, Bendix EC80ESP+ 2nd CAN: Z228999, Bendix EC80ESP+ Integrated TPMS: Z228999, Bendix EC80ESP 6S/6M: Z266494, Bendix EC80ESP PLC: Z266494, Bendix EC80ESP 2nd CAN: Z266494, Bendix EC80ESP CAN Gateway: Z266494, Bendix EC80ESP 4S/4M: Z286098, Bendix EC80ESP PLC: Z286098
Product Status:
known_affected
Remediations

Mitigation
Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.
mailto:info@Bendix.com

Vendor fix
EC80ESP+ J1708: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ 6S/6M: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ PLC: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ 2nd CAN: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ Integrated TPMS: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP 6S/6M: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP PLC: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP 2nd CAN: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP CAN Gateway: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP 4S/4M: Z286098 users should update their firmware to version Z302579.

Vendor fix
EC80ESP PLC: Z286098 users should update their firmware to version Z302579.

Relevant CWE: CWE-121 Stack-based Buffer Overflow


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 7.5 HIGH CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 7.7 HIGH CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVE-2026-68967

The affected product is vulnerable to an out-of-bounds write, which could allow an attacker to deliver a payload that could establish an arbitrary write primitive, which could crash the ECU.

View CVE Details


Affected Products

Bendix EC80 Brake ECU
Vendor:
Bendix
Product Version:
Bendix EC80ESP+ J1708: Z228999, Bendix EC80ESP+ 6S/6M: Z228999, Bendix EC80ESP+ PLC: Z228999, Bendix EC80ESP+ 2nd CAN: Z228999, Bendix EC80ESP+ Integrated TPMS: Z228999, Bendix EC80ESP 6S/6M: Z266494, Bendix EC80ESP PLC: Z266494, Bendix EC80ESP 2nd CAN: Z266494, Bendix EC80ESP CAN Gateway: Z266494, Bendix EC80ESP 4S/4M: Z286098, Bendix EC80ESP PLC: Z286098
Product Status:
known_affected
Remediations

Mitigation
Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.
mailto:info@Bendix.com

Vendor fix
EC80ESP+ J1708: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ 6S/6M: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ PLC: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ 2nd CAN: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ Integrated TPMS: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP 6S/6M: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP PLC: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP 2nd CAN: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP CAN Gateway: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP 4S/4M: Z286098 users should update their firmware to version Z302579.

Vendor fix
EC80ESP PLC: Z286098 users should update their firmware to version Z302579.

Relevant CWE: CWE-787 Out-of-bounds Write


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N

CVE-2026-71396

The affected product uses hard-coded credentials, which could allow an attacker to disable automatic traction control.

View CVE Details


Affected Products

Bendix EC80 Brake ECU
Vendor:
Bendix
Product Version:
Bendix EC80ESP+ J1708: Z228999, Bendix EC80ESP+ 6S/6M: Z228999, Bendix EC80ESP+ PLC: Z228999, Bendix EC80ESP+ 2nd CAN: Z228999, Bendix EC80ESP+ Integrated TPMS: Z228999, Bendix EC80ESP 6S/6M: Z266494, Bendix EC80ESP PLC: Z266494, Bendix EC80ESP 2nd CAN: Z266494, Bendix EC80ESP CAN Gateway: Z266494, Bendix EC80ESP 4S/4M: Z286098, Bendix EC80ESP PLC: Z286098
Product Status:
known_affected
Remediations

Mitigation
Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.
mailto:info@Bendix.com

Vendor fix
EC80ESP+ J1708: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ 6S/6M: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ PLC: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ 2nd CAN: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP+ Integrated TPMS: Z228999 users should update their firmware to version Z300822.

Vendor fix
EC80ESP 6S/6M: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP PLC: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP 2nd CAN: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP CAN Gateway: Z266494 users should update their firmware to version Z302578.

Vendor fix
EC80ESP 4S/4M: Z286098 users should update their firmware to version Z302579.

Vendor fix
EC80ESP PLC: Z286098 users should update their firmware to version Z302579.

Relevant CWE: CWE-798 Use of Hard-coded Credentials


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 5.4 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
4.0 5.3 MEDIUM CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N

Acknowledgments

  • Ben Gardiner of NMFTA reported these vulnerabilities to CISA

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.

Locate control system networks and remote devices behind firewalls and isolating them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.

Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.

Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.


Revision History

  • Initial Release Date: 2026-08-25
Date Revision Summary
2026-08-25 1 Initial Publication

Legal Notice and Terms of Use